Abstract:
Abstract The precise and accurate measurement of implant wear, acetabular cup anteversion and inclination from routine anterior-posterior radiographs still poses a challenge. Current approaches suffer from time-consuming procedures accompanied by low and observer-dependent accuracy and precision. We present and validate a novel, automated method for determining total hip arthroplasty parameters by comparing its accuracy and precision with methods in contemporary scientific literature. The algorithm uses CAD-model-based two dimensional-three dimensional (2D-3D)-registration supported by convolutional neural networks. Two in-vitro experimental set-ups were designed to validate the proposed 2D-3D-method. The set-ups provided 84 predefined wear values and 24 configurations of anteversion and inclination in 114 radiographs. Accuracy and precision were evaluated by systematically comparing the predefined ground truth and the automatically calculated values from in-vitro X-rays. In addition, an algorithm was developed and validated against physician's measurements on clinical X-rays to determine the inclination of the interteardrop (ITL) and biischial line (BL) to account for the individual patient's pelvic rotation in the frontal plane. Using X-rays from experimental set-ups, the determined mean error was 0.014?mm (standard deviation: 0.020?mm; root-mean-square-error: 0.024?mm) for wear in pelvic position, ?0.01° (0.24°; 0.23°) for radiographic cup anteversion, and 0.11° (0.38°; 0.39°) for radiographic cup inclination. The inclination of ITL and BL was automatically determined in all clinical X-rays with excellent interclass correlation coefficients of 0.95 and 0.91, respectively. The presented algorithm allows the accurate and precise evaluation of total hip arthroplasty parameters without additional equipment. The method might help to investigate different implant designs, biomaterials, and surgical techniques with greater objectivity.
Reference:
Accurate determination of hip implant wear, cup anteversion and inclination through AI automated 2D-3D registration (Stefan Klebingat, Tanja Bien, Janine Hürtgen, Priyanka Grover, Marcel Dreischarf, Shareef Alkhateeb, Marcus Jäger, Georg Rose), In Journal of Orthopaedic Research, volume 41, 2023.
Bibtex Entry:
@article{klebingat_accurate_2023,
	title = {Accurate determination of hip implant wear, cup anteversion and inclination through {AI} automated 2D-3D registration},
	volume = {41},
	issn = {0736-0266},
	url = {https://doi.org/10.1002/jor.25538},
	doi = {10.1002/jor.25538},
	abstract = {Abstract The precise and accurate measurement of implant wear, acetabular cup anteversion and inclination from routine anterior-posterior radiographs still poses a challenge. Current approaches suffer from time-consuming procedures accompanied by low and observer-dependent accuracy and precision. We present and validate a novel, automated method for determining total hip arthroplasty parameters by comparing its accuracy and precision with methods in contemporary scientific literature. The algorithm uses CAD-model-based two dimensional-three dimensional (2D-3D)-registration supported by convolutional neural networks. Two in-vitro experimental set-ups were designed to validate the proposed 2D-3D-method. The set-ups provided 84 predefined wear values and 24 configurations of anteversion and inclination in 114 radiographs. Accuracy and precision were evaluated by systematically comparing the predefined ground truth and the automatically calculated values from in-vitro X-rays. In addition, an algorithm was developed and validated against physician's measurements on clinical X-rays to determine the inclination of the interteardrop (ITL) and biischial line (BL) to account for the individual patient's pelvic rotation in the frontal plane. Using X-rays from experimental set-ups, the determined mean error was 0.014?mm (standard deviation: 0.020?mm; root-mean-square-error: 0.024?mm) for wear in pelvic position, ?0.01° (0.24°; 0.23°) for radiographic cup anteversion, and 0.11° (0.38°; 0.39°) for radiographic cup inclination. The inclination of ITL and BL was automatically determined in all clinical X-rays with excellent interclass correlation coefficients of 0.95 and 0.91, respectively. The presented algorithm allows the accurate and precise evaluation of total hip arthroplasty parameters without additional equipment. The method might help to investigate different implant designs, biomaterials, and surgical techniques with greater objectivity.},
	number = {9},
	urldate = {2023-12-20},
	journal = {Journal of Orthopaedic Research},
	author = {Klebingat, Stefan and Bien, Tanja and Hürtgen, Janine and Grover, Priyanka and Dreischarf, Marcel and Alkhateeb, Shareef and Jäger, Marcus and Rose, Georg},
	month = sep,
	year = {2023},
	keywords = {anteversion and inclination, arthroplasty-hip, artificial intellligence, Diagnostic Imaging, implant wear},
	pages = {1985--1995},
	annote = {The following values have no corresponding Zotero field:journalAbbreviation: J Orthop ResPB - John Wiley \& Sons, Ltd}
}